POWER WINDOW MASTER SWITCH INSPECTION


  1. INSPECT POWER WINDOW MASTER SWITCH


    1. A01BH3ME04

      Remove the power window master switch.

    2. Measure the resistance when the switch is operated according to the value(s) in the table below.

      Standard resistance
      UNLOCK position (Window Lock)
      Tester Connection Switch Condition Specified Condition

      6 - 13

      1 - 15

      UP Below 1 Ω

      1 - 13

      1 - 15

      OFF Below 1 Ω

      1 - 13

      6 - 15

      DOWN Below 1 Ω
      LOCK position (Window Lock)
      Tester Connection Switch Condition Specified Condition
      6 - 13 UP Below 1 Ω
      13 - 15 OFF Below 1 Ω
      6 - 15 DOWN Below 1 Ω