FRONT DOOR LOCK INSPECTION


  1. INSPECT FRONT DOOR LOCK ASSEMBLY (DRIVER SIDE)


    1. A01BC95E01

      Inspect the door lock motor & unlock detection switch.


      1. Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        LHD Models
        Tester Connection Door Lock Condition Specified Condition

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 4

        ON (Door lock set to UNLOCK) 7 - 8 (Below 1 Ω)

        Battery positive (+) → Terminal 4

        Battery negative (-) → Terminal 1

        OFF (Door lock set to LOCK) 7 - 8 (10 kΩ or higher)
      2. A01BEYHE01

        Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        RHD Models
        Tester Connection Door Lock Condition Specified Condition

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 4

        ON (Door lock set to UNLOCK) 7 - 8 (Below 1 Ω)

        Battery positive (+) → Terminal 4

        Battery negative (-) → Terminal 1

        OFF (Door lock set to LOCK) 7 - 8 (10 kΩ or higher)
    2. A01BBFRE01

      Inspect the key lock and unlock switch.


      1. Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        LHD Models
        Tester Connection Door Lock Condition Specified Condition
        10 - 7 ON (Door lock set to UNLOCK) Below 1 Ω
        9 - 7 OFF (Door lock set to LOCK) Below 1 Ω
      2. A01BDWIE01

        Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        RHD Models
        Tester Connection Door Lock Condition Specified Condition
        5 - 8 ON (Door lock set to UNLOCK) Below 1 Ω
        6 - 8 OFF (Door lock set to LOCK) Below 1 Ω
  2. REMOVE FRONT DOOR LOCK ASSEMBLY (FRONT PASSENGER SIDE)


    1. A01BEYHE01

      Inspect the door lock motor.


      1. Apply battery voltage and check operation of the door lock motor.

        Standard
        LHD Models
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 4

        Battery negative (-) → Terminal 1

        Lock

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 4

        Unlock
      2. A01BC95E01

        Apply battery voltage and check operation of the door lock motor.

        Standard
        RHD Models
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 4

        Battery negative (-) → Terminal 1

        Lock

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 4

        Unlock
    2. A01BDWIE01

      Inspect the key lock and unlock switch.


      1. Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        LHD Models
        Tester Connection Door Lock Condition Specified Condition
        5 - 8 ON (Door lock set to UNLOCK) Below 1 Ω
        6 - 8 OFF (Door lock set to LOCK) Below 1 Ω
      2. A01BBFR

        Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        RHD Models
        Tester Connection Door Lock Condition Specified Condition
        10 - 7 ON (Door lock set to UNLOCK) Below 1 Ω
        9 - 7 OFF (Door lock set to LOCK) Below 1 Ω