INSPECT NO. 2 INTEGRATION RELAY (HD-LP NO. 1)
Check the HD-LP No. 1 relay.
Remove the H-LP RH-LO fuse.
| *1 | H-LP RH-LO Fuse |
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.
Install the H-LP RH-LO fuse.
INSPECT NO. 2 INTEGRATION RELAY (DIM NO. 1)
Check the H-LP RH-HI fuse.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the H-LP RH-HI fuse.
Check the DIM No. 1 relay.
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.
INSPECT NO. 2 INTEGRATION RELAY (HD-LP NO. 2)
Check the HD-LP No. 2 relay.
Remove the H-LP LH-LO fuse.
| *1 | H-LP LH-LO Fuse |
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.
Install the H-LP LH-LO fuse.
INSPECT NO. 2 INTEGRATION RELAY (DIM NO. 2)
Check the H-LP LH-HI fuse.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the H-LP LH-HI fuse.
Check the DIM No. 2 relay.
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.
INSPECT NO. 2 INTEGRATION RELAY (IG2)
Check the IG2-MAIN fuse.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the IG2-MAIN fuse.
Check the IG2 relay.
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.
INSPECT NO. 2 INTEGRATION RELAY (DRL)
Check the DRL fuse.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the DRL fuse.
Check the DRL relay.
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.
INSPECT NO. 2 INTEGRATION RELAY (ACC)
Check the ACC relay.
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.
INSPECT NO. 2 INTEGRATION RELAY (100V)
Check the 100V fuse.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the 100V fuse.
Check the 100V relay.
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.
INSPECT NO. 2 INTEGRATION RELAY (FR FOG)
Check the FR FOG relay.
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.
INSPECT NO. 2 INTEGRATION RELAY (DOME CUT)
Check the DOME CUT relay.
| *a | Component without harness connected (No. 2 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 2 integration relay.