INSPECT INTEGRATION NO.1 RELAY
Measure the resistance of the EFI MAIN relay.
Using an ohmmeter, measure the resistance.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the battery positive (+) lead to terminal 1J-2 and negative (-) lead to terminal 1J-3. Using an ohmmeter, measure the resistance.
| Standard resistance | ||||
|---|---|---|---|---|
|
If the resistance is not as specified, replace the integration relay.
Measure the resistance of the EDU relay.
Using an ohmmeter, measure the resistance.
| Standard resistance | ||||
|---|---|---|---|---|
|
If the resistance is not as specified, replace the integration relay.
Measure the voltage of the EDU relay.
Connect the battery positive (+) lead to terminal 1J-4.Using a voltmeter, measure the voltage according to the values in the table below.
Note
While using the battery for inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
If the voltage is not as specified, replace the integration relay.
Connect the battery positive (+) lead to terminal 1J-4 and battery negative (-) lead to terminal 1J-7. Using a voltmeter, measure the voltage.
Note
While using the battery for inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
| Standard voltage | ||||
|---|---|---|---|---|
|
If the voltage is not as specified, replace the integration relay.