2TR-FE STARTING SERVICE DATA

Starter (for 1.4 kW Type)
No-load characteristics Current: 90 A or less at 11.5 V
Brush length Standard: 15.5 mm (0.610 in.)
Minimum: 8.5 mm (0.335 in.)
Brush spring load Standard: 18 to 24 N (1.8 to 2.4 kgf, 4.0 to 5.3 lbf)
Minimum: 12 N (1 kgf, 2.7 lbf)
Commutator circle runout Maximum: 0.05 mm (0.00197 in.)
Commutator diameter Standard: 30.0 mm (1.18 in.)
Minimum: 29.0 mm (1.14 in.)
Undercut depth Standard: 0.6 mm (0.0236 in.)
Minimum: 0.2 mm (0.00787 in.)
Starter (for 1.6 kW Type)
No-load characteristics Current: 90 A or less at 11.5 V
Commutator length Standard: 3.1 mm (0.122 in.)
Maximum: 3.8 mm (0.150 in.)
Brush length Standard: 9.0 mm (0.354 in.)
Minimum: 4.0 mm (0.158 in.)
snap ring Maximum length: 5.0 mm (0.197 in.)
Starter Relay
Starter relay 3 - 5: 10 kΩ or higher
3 - 5: Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
Ignition Switch
Ignition switch LOCK: Between all terminals 10 kΩ or higher
ACC: 2 (AM1) - 3 (ACC) Below 1 Ω

ON: 2 (AM1) - 3 (ACC) Below 1 Ω

ON: 2 (AM1) - 4 (IG1) Below 1 Ω

ON: 5 (IG2) - 6 (AM2) Below 1 Ω

START: 1 (ST1) - 2 (AM1) Below 1 Ω

START: 1 (ST1) - 4 (IG1) Below 1 Ω

START: 5 (IG2) - 6 (AM2) Below 1 Ω

START: 5 (IG2) - 7 (ST2) Below 1 Ω