| Radiator reservoir cap sub-assembly | Standard Judgment Criterion | Standard value (for brand-new cap) |
94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17.7 psi) |
| Minimum standard value (for used cap) |
79 kPa (0.8 kgf/cm2, 11.4 psi) |
| No. 1 cooling fan motor | Standard Current | 17 to 23 A at 20°C (68°F) | |
| No. 2cooling fan motor | Standard Current | 17 to 23 A at 20°C (68°F) | |
| Engine coolant temperature sensor | Standard resistance | 1 - 2 | 2.32 to 2.59 kΩ at 20 °C (68 °F) |
| 0.310 to 0.326 kΩ at 80 °C (176 °F) | |||
| Thermostat | Valve opening temperature | 80 to 84 °C (176 to 183 °F) |
| Valve lift | 10 mm (0.394 in.) or more at 95 °C (203 °F) |