1KD-FTV COOLING SERVICE DATA

Thermostat Valve opening temperature 80 to 84°C (176 to 183°F)
Valve lift 10 mm (0.39 in.) or more at 95°C (203°F)
Radiator cap Relief valve opening pressure Standard

93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)

Minimum

78.5 kPa (0.80 kgf/cm2, 11.38 psi)

No. 1 cooling fan motor Current Standard

4 to 23 A

(when the A/C switch is on (MAX COOL and the magnet clutch is operating))

17 to 23 A (20°C (68°F)) at 12V

(when the battery is connected to the fan motor connector)

8 to 24 A

(when the water temperature sensor connector is disconnected)

No. 2 cooling fan motor Current Standard

4 to 23 A

(when the A/C switch is on (MAX COOL and the magnet clutch is operating))

17 to 23 A (20°C (68°F)) at 12V

(when the battery is connected to the fan motor connector)

(when the water temperature sensor connector is disconnected)

8 to 24 A

(when the water temperature sensor connector is disconnected)

Cooling fan switch Resistance 2.32 to 2.59 Ω at 20°C (68°F)
0.310 to 0.326 Ω at 80°C (176°F)
Cooling fan ECU Voltage Standard

11 to 14 V

(when turn the engine switch on (IG))