1KD-FTV EMISSION CONTROL SERVICE DATA

EGR VALVE (w/ DPF)
Tester Connection Condition Specified Condition
5 (M-) - 4 (M+) 25°C (77°F) 0.3 to 100 Ω
ELECTRIC EGR CONTROL VALVE (w/o DPF)
Item Tester Connection Condition Specified Condition
Electric EGR control valve 1 - 2 20°C (68°F) 11 to 13 Ω
EGR valve position sensor 1 (VC) - 2 (E2) 20°C (68°F) 4.0 to 6.0 kΩ
EGR valve condition 3 (EGLS) - 2 (E2)

20°C (68°F)

Fully opened

3.9 kΩ

20°C (68°F)

Fully closed

1.0 kΩ
VACUUM SWITCHING VALVE
Item Tester Connection Condition Specified Condition
Vacuum switching valve 1 - 2 20°C (68°F) 37 to 44 Ω
No. 2 vacuum switching valve 1 - 2 20°C (68°F) 33 to 39 Ω
EXHAUST GAS TEMPERATURE SENSOR (for DPF)
Item Tester Connection Condition Specified Condition
Exhaust gas temperature sensor 1 - 2 50°C (122°F) 82 to 137 kΩ
No. 2 exhaust gas temperature sensor 1 - 2 50°C (122°F) 82 to 137 kΩ
No. 3 exhaust gas temperature sensor 1 - 2 50°C (122°F) 82 to 137 kΩ
EXHAUST FUEL ADDITION INJECTOR (for DPF)
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 7.1 to 7.9 Ω
DPF SWITCH (for DPF)
Tester Connection Switch Connection Specified Condition
3 - 4 Switch OFF 10 kΩ higher
Switch ON Below 1Ω
AIR FUEL RATIO SENSOR (for DPF)
Tester Connection Condition Specified Condition
1 (HAF2) - 2 (+B) 20°C (68°F) 1.8 to 3.4 Ω