1KD-FTV FUEL SERVICE DATA

Fuel injector
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.42 to 0.52 Ω
Fuel supply pump
Item Tester Connection Condition Specified Condition
Suction control valve 1 - 2 20°C (68°F) 1.9 to 2.3 Ω
Common rail
Item Tester Connection Condition Specified Condition
Fuel pressure sensor 2 - 3 25°C (77°F) 16.4 kΩ or less
5 - 4 25°C (77°F) 16.4 kΩ or less
1 - 2 25°C (77°F) 3 kΩ or less
6 - 5 25°C (77°F) 3 kΩ or less
Pressure discharge valve 1 - 2 20°C (68°F) 0.85 to 1.05 Ω
Fuel filter
Item Tester Connection Condition Specified Condition
Level warning switch 1 - 2 Float upper end position Below 1 Ω
Float lower end position 10 kΩ or more
Fuel temperature sensor
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.21 to 2.69 kΩ
80°C (176°F) 0.287 to 0.349 kΩ