1KD-FTV INTAKE SERVICE DATA

Manifold absolute pressure sensor
Condition Tester Connection Specified Condition
ECM output voltage D51-3 (VC (+)) - D51-1 (E2 (-)) 4.75 to 5.25 V
Applied Vacuum - -
13.3 kPa (100 mmHg, 3.93 in.Hg) D75-5 (PIM(+)) - D75-16 (EPIM(-)) 0.1 to 0.2 V
26.6 kPa (200 mmHg, 7.85 in.Hg) 0.2 to 0.4 V
40 kPa (300 mmHg, 11.8 in.Hg) 0.4 to 0.8 V
Applied Pressure - -

19.6 kPa (0.20 kgf*cm2, 2.84 psi)

D75-5 (PIM(+)) - D75-16 (EPIM(-)) 0.1 to 0.3 V

39.2 kPa (0.40 kgf*cm2, 5.68 psi)

0.3 to 0.6 V

58.8 kPa (0.60 kgf*cm2, 8.53 psi)

0.6 to 0.8 V

78.5 kPa (0.80 kgf*cm2, 11.4 psi)

0.8 to 1.0 V

98 kPa (1.00 kgf*cm2, 14.2 psi)

1.0 to 1.2 V
Turbocharger pressure
Condition Specified Condition
Engine speed (approximately 4450 rpm)

10 to 40 kPa (0.10 to 0.41 kgf*cm2, 1.4 to 5.8 psi)