KNOCK SENSOR INSPECTION


  1. INSPECT KNOCK CONTROL SENSOR


    1. A01BEESE02

      Check the resistance.


      1. Using an ohmmeter, measure the resistance between the terminals.

        Standard resistance
        Tester Connection Specified Condition
        1 (Ground) - 2 (Output) 120 to 280 kΩ at 20 °C (68 °F)

        If the result is not as specified, replace the knock sensor.