RELAY ON-VEHICLE INSPECTION


  1. INSPECT NO. 2 INTEGRATION RELAY (HD-LP NO. 1)


    1. Check the HD-LP No. 1 relay.


      1. Remove the H-LP RH-LO fuse.

      2. A01BG9PE01
        Text in Illustration
        *1 H-LP RH-LO Fuse
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        d-2 - 12D-3 Battery voltage not applied to terminals d-2 and 12D-4 10 kΩ or higher
        Battery voltage applied to terminals d-2 and 12D-4 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.

      3. Install the H-LP RH-LO fuse.

  2. INSPECT NO. 2 INTEGRATION RELAY (DIM NO. 1)


    1. Check the H-LP RH-HI fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        H-LP RH-HI fuse Always Below 1 Ω

        If the result is not as specified, replace the H-LP RH-HI fuse.

    2. Check the DIM No. 1 relay.


      1. A01BG6KE03
        Text in Illustration
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12A-1 - 12C-2 Battery voltage not applied to terminals 12C-3 and 12C-1 10 kΩ or higher
        Battery voltage applied to terminals 12C-3 and 12C-1 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.

  3. INSPECT NO. 2 INTEGRATION RELAY (HD-LP NO. 2)


    1. Check the HD-LP No. 2 relay.


      1. Remove the H-LP LH-LO fuse.

      2. A01BG9PE05
        Text in Illustration
        *1 H-LP LH-LO Fuse
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        c-2 - 12B-9 Battery voltage not applied to terminals c-2 and 12B-10 10 kΩ or higher
        Battery voltage applied to terminals c-2 and 12B-10 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.

      3. Install the H-LP LH-LO fuse.

  4. INSPECT NO. 2 INTEGRATION RELAY (DIM NO. 2)


    1. Check the H-LP LH-HI fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        H-LP LH-HI fuse Always Below 1 Ω

        If the result is not as specified, replace the H-LP LH-HI fuse.

    2. Check the DIM No. 2 relay.


      1. A01BG6KE04
        Text in Illustration
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12A-1 - 12B-12 Battery voltage not applied to terminals 12B-8 and 12B-11 10 kΩ or higher
        Battery voltage applied to terminals 12B-8 and 12B-11 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.

  5. INSPECT NO. 2 INTEGRATION RELAY (IG2)


    1. Check the IG2-MAIN fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        IG2-MAIN fuse Always Below 1 Ω

        If the result is not as specified, replace the IG2-MAIN fuse.

    2. Check the IG2 relay.


      1. A01BG6KE05
        Text in Illustration
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12A-1 - 12D-1 Battery voltage not applied to terminals 12D-2 and 12E-4 10 kΩ or higher
        Battery voltage applied to terminals 12D-2 and 12E-4 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.

  6. INSPECT NO. 2 INTEGRATION RELAY (DRL)


    1. Check the DRL fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        DRL fuse Always Below 1 Ω

        If the result is not as specified, replace the DRL fuse.

    2. Check the DRL relay.


      1. A01BG6KE05
        Text in Illustration
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12A-1 - 12D-6 Battery voltage not applied to terminals 12E-12 and 12D-7 10 kΩ or higher
        Battery voltage applied to terminals 12E-12 and 12D-7 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.

  7. INSPECT NO. 2 INTEGRATION RELAY (ACC)


    1. Check the ACC relay.


      1. A01BG6KE06
        Text in Illustration
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12E-7 - 12E-9 Battery voltage not applied to terminals 12E-8 and 12E-4 10 kΩ or higher
        Battery voltage applied to terminals 12E-8 and 12E-4 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.

  8. INSPECT NO. 2 INTEGRATION RELAY (100V)


    1. Check the 100V fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        100V fuse Always Below 1 Ω

        If the result is not as specified, replace the 100V fuse.

    2. Check the 100V relay.


      1. A01BG6KE07
        Text in Illustration
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12A-1 - 12E-3 Battery voltage not applied to terminals 12E-1 and 12E-4 10 kΩ or higher
        Battery voltage applied to terminals 12E-1 and 12E-4 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.

  9. INSPECT NO. 2 INTEGRATION RELAY (FR FOG)


    1. Check the FR FOG relay.


      1. A01BG6KE08
        Text in Illustration
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12B-3 - 12B-1 Battery voltage not applied to terminals 12B-6 and 12C-4 10 kΩ or higher
        Battery voltage applied to terminals 12B-6 and 12C-4 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.

  10. INSPECT NO. 2 INTEGRATION RELAY (DOME CUT)


    1. Check the DOME CUT relay.


      1. A01BG6KE09
        Text in Illustration
        *a

        Component without harness connected

        (No. 2 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        12C-7 - 12C-6 Battery voltage not applied to terminals 12C-8 and 12C-5 10 kΩ or higher
        Battery voltage applied to terminals 12C-8 and 12C-5 Below 1 Ω

        If the result is not as specified, replace the No. 2 integration relay.