INSPECT INTEGRATION NO.1 RELAY
Measure the resistance of the fan No.3 relay.
Using an ohmmeter, measure the resistance according to the values in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the battery positive (+) lead to terminal 1I-2 and the negative (-) lead to terminal 1I-3. Using an ohmmeter, measure the resistance according to the value in the table below.
| Standard resistance | ||||
|---|---|---|---|---|
|
If the resistance is not as specified, replace the integration relay.
Measure the resistance of the HORN relay.
Using an ohmmeter, measure the resistance according to the value in the table below.
| Standard resistance | ||||
|---|---|---|---|---|
|
If the resistance is not as specified, replace the integration relay.
Measure the voltage of the HORN relay.
Disconnect the HAZ-HORN fuse. Connect the battery positive (+) lead to terminal HAZ-HORN fuse 2 (+). Using a voltmeter, measure the voltage according to the values in the table below.
Note
While using the battery for inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
If the voltage is not as specified, replace the integration relay.
Connect the battery positive (+) lead to terminal HAZ-HORN fuse 2 (+) and battery negative (-) lead to terminal 1I-7.Using a voltmeter, measure the voltage according to the value in the table below.
Note
While using the battery for inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
| Standard voltage | ||||
|---|---|---|---|---|
|
If the voltage is not as specified, replace the integration relay.
Measure the resistance of the EFI MAIN relay.
Using an ohmmeter, measure the resistance according to the values in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the battery positive (+) lead to terminal 1J-2 and the negative (-) lead to terminal 1J-3. Using an ohmmeter, measure the resistance according to the value in the table below.
| Standard resistance | ||||
|---|---|---|---|---|
|
If the resistance is not as specified, replace the integration relay.
Measure the resistance of the A/F relay.
Using an ohmmeter, measure the resistance according to the values in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the resistance is not as specified, replace the integration relay.
Connect the battery positive (+) lead to terminal 1J-6 and the negative (-) lead to terminal 1J-7. Using an ohmmeter, measure the resistance according to the value in the table below.
| Standard resistance | ||||
|---|---|---|---|---|
|
If the resistance is not as specified, replace the integration relay.