INTEGRATION RELAY INSPECTION


  1. INSPECT NO. 1 INTEGRATION RELAY (C/OPN)


    1. A01BCI3E16
      Text in Illustration
      *a

      Component without harness connected

      (No. 1 Integration Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      10A-1 - 10A-4 Battery voltage not applied to terminals 10A-2 and 10A-3 10 kΩ or higher
      Battery voltage applied to terminals 10A-2 and 10A-3 Below 1 Ω

      If the result is not as specified, replace the No. 1 integration relay.

  2. INSPECT NO. 1 INTEGRATION RELAY (EFI)


    1. Check EFI NO. 1 fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        EFI NO. 1 fuse Always Below 1 Ω

        If the result is not specified, replace the EFI NO. 1 fuse.

    2. Check the EFI relay.


      1. A01BCI3E16
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        10C-1 - 10A-8 Battery voltage not applied to terminals 10A-6 and 10A-7 10 kΩ or higher
        Battery voltage applied to terminals 10A-6 and 10A-7 Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

  3. INSPECT NO. 1 INTEGRATION RELAY (INJ)


    1. A01BCI3E16
      Text in Illustration
      *a

      Component without harness connected

      (No. 1 Integration Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      10B-1 - 10B-4 Battery voltage not applied to terminals 10B-2 and 10B-3 10 kΩ or higher
      Battery voltage applied to terminals 10B-2 and 10B-3 Below 1 Ω

      If the result is not as specified, replace the No. 1 integration relay.

  4. INSPECT NO. 1 INTEGRATION RELAY (A/F HTR)


    1. A01BCI3E16
      Text in Illustration
      *a

      Component without harness connected

      (No. 1 Integration Relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      10B-5 - 10B-8 Battery voltage not applied to terminals 10B-6 and 10B-7 10 kΩ or higher
      Battery voltage applied to terminals 10B-6 and 10B-7 Below 1 Ω

      If the result is not as specified, replace the No. 1 integration relay.