INSPECT MASS AIR FLOW METER
Check the output voltage.
| *a | Air |
Apply battery voltage across terminals 1 (+B) and 2 (E2G).
Note
While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
Using a voltmeter, connect the positive (+) tester probe to terminal 3 (VG) and the negative (-) tester probe to terminal 2 (E2G).
Blow air into the mass air flow meter and check that the voltage fluctuates.
If the voltage does not fluctuate, replace the mass air flow meter.
Check the resistance.
| *a | Component without harness connected (Mass Air Flow Meter) |
| *b | Resistance |
| *c | Temperature |
| *d | Acceptable Range |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the mass air flow meter.