COMBINATION METER REMOVAL


  1. REMOVE INSTRUMENT CLUSTER FINISH PANEL NO.1

    A01KIOEE02
    Text in Illustration
    *a Protective Tape

    1. Put protective tape around the instrument cluster finish panel.

    2. Using a moulding remover, disengage the 6 claws and remove the instrument cluster finish panel.

  2. REMOVE COMBINATION METER ASSEMBLY

    A01KIM6

    1. Remove the 3 screws and pull the combination meter rearward to remove it.

    2. Disconnect the 2 connectors.