AIR CONDITIONING PANEL REMOVAL


  1. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY CENTER


    1. A01KFR6E01
      Text in Illustration
      *a 3 Clips
      *b 6 Claws

      Disengage the 3 clips and 6 claws.

    2. Disconnect the connectors and remove the instrument cluster finish panel sub-assembly center.

  2. REMOVE HEATER CONTROL LEVER KNOB


    1. A01KI1P

      Remove the 4 heater control lever knobs.

  3. REMOVE HEATER CONTROL NAME PLATE


    1. A01KEMNE02
      Text in Illustration
      *a 4 Claws

      Release the 4 claw fittings, remove the heater control name plate.

  4. REMOVE HEATER OR BOOST VENTILATOR CONTROL ASSEMBLY


    1. A01KGGE

      Spread the clamp's claws of the defroster damper control cable and disconnect the inner cable.

    2. A01KFBV

      Spread the clamp's claws of the air inlet damper control cable and disconnect the inner cable.

    3. A01KHRBE03
      Text in Illustration
      *a Claw

      Release the claw fitting, remove the heater blower switch assembly and bulb.

    4. A01KG87

      Remove the 3 screws and heater or boost ventilator control assembly.

    5. A01KFVW

      Spread the clamp's claws of the air mix damper control cable and disconnect the inner cable.

    6. Disconnect the connector, remove the heater or boost ventilator control assembly.