| DTC Code | DTC Name |
|---|---|
| C0278/11 | Open in ABS Solenoid Relay Circuit |
| C0279/12 | Short to B+ in ABS Solenoid Relay Circuit |
DESCRIPTION
This relay supplies power to each ABS solenoid. After the ignition switch is turned ON, if the initial check is OK, the relay goes on.
| DTC No. | DTC Detecting Condition | Trouble Area |
|---|---|---|
| C0278/11 | Conditions of 1 or 2 continue for 0.2 seconds or more.
|
|
| C0279/12 | Immediately after ECU IG1 terminal becomes ON, when the solenoid relay is OFF, and when the condition that the solenoid relay contact is ON has been continued for 0.2 seconds or more. |
WIRING DIAGRAM
INSPECTION PROCEDURE
Tech Tips
Start the inspection from step 1 in case of using the intelligent tester and start from step 2 in case of not using the intelligent tester.
PROCEDURE
DO ACTIVE TEST OF INTELLIGENT TESTER (ABS SOLENOID RELAY OPERATION)
Select the ACTIVE TEST mode on the intelligent tester.
Check the operation sound of the ABS solenoid relay when operating it with the intelligent tester.
| OK |
|---|
| The operation sound of the ABS solenoid relay should be heard. |
| OK |
|
CHECK CONTINUITY (ABS SOLENOID RELAY - SKID CONTROL ECU) Click here |
| NG |
|
CHECK TERMINAL VOLTAGE
| *1 | R/B No. 2 |
Remove the ABS solenoid relay from R/B No. 2.
Measure the voltage between terminal 5 of R/B No. 2 (for ABS solenoid relay) and body ground.
| OK |
|---|
| Voltage: 10 - 14 V |
| NG |
|
INSPECT FUSE (ABS 2 OF R/B No. 2) Click here |
| OK |
|
INSPECT ABS SOLENOID RELAY
Check continuity between each terminal of ABS solenoid relay.
| OK | ||||
|---|---|---|---|---|
|
Apply battery positive voltage between terminals 1 and 2.
| *a | Open |
| *b | Continuity |
Check continuity between terminals 3 and 5 of ABS solenoid relay.
| OK | ||
|---|---|---|
|
| NG |
|
REPLACE ABS SOLENOID RELAY |
| OK |
|
CHECK CONTINUITY (ABS SOLENOID RELAY - SKID CONTROL ECU)
Disconnect the 2 connectors from the skid control ECU.
| *1 | ABS MTR Relay | *2 | Skid control ECU |
| *3 | R/B No. 2 | *4 | Brake Actuator |
Check continuity between terminal 3 of R/B No. 2 (for ABS solenoid relay) and terminals S6 - 5, 6, 10, 11, 12, and S7 - 1 and 2 of skid control ECU.
| OK |
|---|
| Continuity |
| NG |
|
REPAIR OR REPLACE HARNESS OR BRAKE ACTUATOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (ABS SOLENOID RELAY - SKID CONTROL ECU)
Check for open and short circuit in harness and connector between ABS solenoid relay and skid control ECU Click here.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK RECONFIRM DTC
Check DTC on Click here.
| A | Malfunction Code |
| B | Normal Code |
| B |
|
NO PROBLEM |
| A |
|
CHECK CONTACT CONDITION
| OK |
|
CHECK AND REPLACE SKID CONTROL ECU ASSEMBLY |
| NG |
|
CHECK AND REPAIR HARNESS AND CONNECTOR
INSPECT FUSE (ABS 2 OF R/B No. 2)
| *1 | R/B No. 2 |
| *2 | ABS2 |
Remove ABS2 fuse from the R/B No. 2.
Check continuity of ABS2 fuse.
| OK |
|---|
| Continuity |
| NG |
|
REPLACE FUSE |
| OK |
|
CHECK AND REPAIR HARNESS OR CONNECTOR