SHIFT LEVER ASSEMBLY INSTALLATION


  1. INSTALL FLOOR SHIFT ASSEMBLY


    1. A01KGVF

      Install the floor shift assembly to the floor with the 4 bolts.

      Torque:
      18 N*m  { 183 kgf*cm, 13 ft.*lbf }
  2. INSTALL FLOOR SHIFT CABLE TRANSMISSION CONTROL SELECT


    1. A01KGIB

      Install the select cable to the shift lever retainer with the clip.

    2. Install the select cable to the floor shift assembly with the clip.

  3. INSTALL FLOOR SHIFT CABLE TRANSMISSION CONTROL SHIFT


    1. A01KHQG

      Install the shift cable to the shift lever retainer with the clip.

    2. Temporarily install the shift cable to the floor shift assembly with the nut.

  4. INSPECT AND ADJUST SHIFT LEVER POSITION


    1. When the shift lever is in N range, check that the shift lever is vertical to the installation surface for the floor shift assembly.

    2. A01KI2T

      Remove the nut, and disconnect the shift cable from the floor shift assembly.

    3. Remove the clip, and disconnect the select cable from the floor shift assembly.

    4. Loosen the lock nut, adjust the shift lever range by turning the ball joint.

    5. Install the select cable to the floor shift assembly with the clip.

    6. Install the shift cable to the floor shift assembly with the nut.

      Torque:
      12 N*m  { 122 kgf*cm, 9 ft.*lbf }
    7. Tighten the lock nut.

      Torque:
      12.7 N*m  { 130 kgf*cm, 9.4 ft.*lbf }
    8. After adjustment, check the following.


      1. The shift lever is vertical to the installation surface for the floor shift assembly.

      2. Shift to each range can be done securely.

      3. When select or shift the shift range, no abnormal force is required.

      4. When select the shift range, the shift lever should return N range smoothly.

      5. No abnormal noise is heard during operation.