COUNTER GEAR INSPECTION


  1. INSPECT COUNTER GEAR


    1. A01KG8W

      Using a micrometer, check the outer diameter shown position in the diagram.

      Standard clearance
      29.984 to 30.000 mm (1.1805 to 1.1811 in.)
      Minimum clearance
      29.984 mm (1.1805 in.)

      If the outer diameter is limit or less, replace the counter gear with a new one.