STARTER RELAY ON-VEHICLE INSPECTION


  1. INSPECT STARTER RELAY ASSEMBLY


    1. A01KGG7E03

      Check the resistance.


      1. Using an ohmmeter, measure the resistance between the terminals.

        Standard resistance
        Tester Connection Specified Condition
        3 - 5 Below 1 Ω (when battery voltage applied to terminals 1 and 2)
        3 - 5 10 kΩ or higher

        If the result is not as specified, replace the starter relay.