OIL LEVEL SENSOR INSPECTION


  1. INSPECT ENGINE OIL LEVEL SENSOR


    1. Check the continuity.


      1. Heat the switch to above 60 °C (140 °F) in an oil bath.

      2. Check the continuity exists between terminals at each float position.

        Float up (switch ON)
        Continuity
        Float down (switch OFF)
        No continuity