THERMOSTAT
Tech Tips
The thermostat is numbered with the valve opening temperature.
Immerse the thermostat in water and gradually heat the water.
Check the valve opening temperature.
| Valve opening temperature |
|---|
| 80 - 84°C (176 - 183°F) |
If the valve opening temperature is not as specified, replace the thermostat.
| *a | Valve Lift |
Check valve lift.
| Valve lift |
|---|
| 10 mm (0.39 in.) or more at 95°C (203°F) |
If the valve lift is not as specified, replace the thermostat.
Check that the valve is fully closed when the thermostat is at low temperatures (below 40°C (104°F)).
If not closed, replace the thermostat.