INSPECT INTAKE AIR TEMPERATURE SENSOR
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
| *1 | Ohmmeter | - | - |
| *a | Resistance | *b | Temperature |
| *c | Acceptable | - | - |
| Standard resistance |
|---|
| 2.21 k to 2.65 kΩ at 20°C (68°F) |
Note
When checking the intake air temperature sensor in water, keep the terminals dry. After the check, wipe the sensor dry.
If the resistance is not as specified, replace the intake air temperature sensor.