| DTC Code | DTC Name |
|---|---|
| P2009 | Intake Manifold Runner Control Circuit Low (Bank 1) |
| P2010 | Intake Manifold Runner Control Circuit High (Bank 1) |
DESCRIPTION
Refer to DTC P2006 on page Click here
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2009 | Open in VSV for swirl control valve circuit for 0.5 seconds (2 trip detection logic) |
|
| P2010 | Short in VSV for swirl control valve circuit for 0.5 seconds (2 trip detection logic) |
|
WIRING DIAGRAM
Refer to DTC P2006 on page Click here
INSPECTION PROCEDURE
Tech Tips
Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Note
If the ECM is replaced, the new ECM needs initialization Click here.
PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE VACUUM SWITCHING VALVE FOR SWIRL CONTROL VALVE)
| *1 | Air |
| *2 | Air Filter |
| *a | VSV: ON |
| *b | VSV: OFF |
Connect an intelligent tester to the DLC3.
Disconnect the vacuum hoses from the VSV for swirl control valve.
Turn the ignition switch ON and turn the tester ON.
Select the following menu items: Powertrain / Engine and ECT / Active Test / Activate the VSV for Swirl Control Valve.
Check the operation.
| OK |
|---|
| When VSV for swirl control valve is ON, air from port E flows out through port F. |
| When VSV for swirl control valve is OFF, air from port E flows out through air filter. |
Reconnect the vacuum hoses to the VSV for swirl control valve.
| OK |
|
CHECK FOR INTERMITTENT PROBLEMS |
| NG |
|
INSPECT VACUUM SWITCHING VALVE FOR SWIRL CONTROL VALVE (RESISTANCE)
| *1 | VSV for Swirl Control Valve Connector |
| *a | Component Side |
| *b | Front View |
Disconnect the S12 VSV for swirl control valve connector.
Measure the resistance of the VSV.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the VSV for swirl control valve connector.
| NG |
|
REPLACE VACUUM SWITCHING VALVE FOR SWIRL CONTROL VALVE |
| OK |
|
INSPECT VACUUM SWITCHING VALVE FOR SWIRL CONTROL VALVE (POWER SOURCE VOLTAGE)
| *1 | VSV for Swirl Control Valve Connector |
| *a | Component Side |
| *b | Front View |
Disconnect the S12 VSV for swirl control valve connector.
Turn the ignition switch ON.
Measure the voltage between the terminal of the wire harness side connector and body ground.
| Standard voltage | ||||
|---|---|---|---|---|
|
Reconnect the VSV Standard resistance connector.
| OK |
|
CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE FOR SWIRL CONTROL VALVE - ECM) Click here |
| NG |
|
CHECK HARNESS AND CONNECTOR (VSV FOR SWIRL CONTROL VALVE - EFI MAIN RELAY)
| *1 | VSV for Swirl Control Valve Connector |
| *2 | Relay Block No.2 |
| *3 | EFI MAIN Relay |
| *a | Wire Harness Side |
| *b | Front View |
Disconnect the S12 VSV for swirl control valve connector.
Remove the EFI MAIN relay from the R/B No. 2.
Check the resistance.
| Standard resistance (Check for open) | ||||
|---|---|---|---|---|
|
| Standard resistance (Check for short) | ||||
|---|---|---|---|---|
|
Reconnect the VSV connector.
Reinstall the EFI MAIN relay.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPAIR OR REPLACE POWER SOURCE CIRCUIT COMPONENTS
CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE FOR SWIRL CONTROL VALVE - ECM)
| *1 | VSV for Swirl Control Valve Connector |
| *2 | ECM Connector |
| *a | Wire Harness Side |
| *b | Front View |
Disconnect the S9 VSV connector.
Disconnect the E6 ECM connector.
Check the resistance.
| Standard resistance (Check for open) | ||||
|---|---|---|---|---|
|
| Standard resistance (Check for short) | ||||
|---|---|---|---|---|
|
Reconnect the VSV for swirl control valve connector.
Reconnect the ECM connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE ECM