1KD-FTV INTAKE (w/o DPF) SERVICE DATA

Turbocharger pressure

Pressure:

10 to 40 kPa (0.10 to 0.41 kgf/cm2, 1.4 to 5.8 psi) at approximately 4450 rpm

Manifold absolute pressure sensor

Voltage:

4.75 to 5.25 V

Manifold absolute pressure sensor

-13.3 kPa (-100 mmHg, -3.94 in.Hg)

-26.6 kPa (-99 mmHg, -7.85 in.Hg)

-40 kPa (-300 mmHg, -11.81 in.Hg)

19.6 kPa (0.20 kgf/cm2, 2.84 psi)

39.2 kPa (0.40 kgf/cm2, 5.69 psi)

58.8 kPa (0.60 kgf/cm2, 8.53 psi)

78.5 kPa (0.80 kgf/cm2, 11.4 psi)

98.0 kPa (1.00 kgf/cm2, 14.2 psi)

Voltage:

0.8 to 1.1 V

0.6 to 1.0 V

0.4 to 0.8 V

1.2 to 1.5 V

1.5 to 1.8 V

1.8 to 2.1 V

1.9 to 2.2 V

2.1 to 2.4 V

Turbo motor driver

3 (+B) - Body ground

Voltage:

9 to 14 V

Turbo motor driver

4 (GND) - Body ground

Resistance:

Below 1 Ω

Turbocharger motor

1 (M-) - 2 (M+)

Resistance:

1 to 100 at 20°C (68°F)

Turbocharger

Axial play of turbine shaft

Radial play of turbine shaft

Maximum axial play:

0.11 mm (0.0043 in.)

Maximum rail play:

0.112 mm (0.0044 in.)