| Turbocharger pressure | Pressure: 5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi) at approximately 4600 rpm |
| Manifold absolute pressure sensor 3 - 1 |
Voltage: 4.75 to 5.25 V |
| Manifold absolute pressure sensor | Voltage: 0.8 to 1.1 V (13.3 kPa (100 mmHg, 3.94 in.Hg)) 0.6 to 1.0 V (26.6 kPa (199 mmHg, 7.85 in.Hg)) 0.4 to 0.8 V (40 kPa (300 mmHg, 11.81 in.Hg)) 1.2 to 1.5 V (19.6 kPa (0.20 kgf/cm2, 2.84 psi)) 1.4 to 1.7 V (39.2 kPa (0.40 kgf/cm2, 5.69 psi)) 1.6 to 1.9V (58.8 kPa (0.60 kgf/cm2, 8.53 psi)) 1.8 to 2.1 V (78.5 kPa (0.80 kgf/cm2, 11.4 psi)) 2.0 to 2.3 V (98.0 kPa (1.00 kgf/cm2, 14.2 psi)) |
| No. 1 vacuum switching valve 1 - 2 1 - Body ground 2 - Body ground |
Resistance: 33 to 39 Ω at 20°C (68°F) 10 kΩ or higher at always 10 kΩ or higher at always |
| No. 2 vacuum switching valve 1 - 2 1 - Body ground 2 - Body ground |
Resistance: 33 to 39 Ω at 20°C (68°F) 10 kΩ or higher at always 10 kΩ or higher at always |
| Turbocharger Axial play of turbine shaft Radial play of turbine shaft |
Maximum axial play: 0.11 mm (0.00433 in.) Maximum radial play: 0.112 mm (0.00441 in.) |