1KD-FTV INTAKE (w/ DPF) SERVICE DATA

Turbocharger pressure

Pressure:

5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi) at approximately 4600 rpm

Manifold absolute pressure sensor

3 - 1

Voltage:

4.75 to 5.25 V

Manifold absolute pressure sensor

Voltage:

0.8 to 1.1 V (13.3 kPa (100 mmHg, 3.94 in.Hg))

0.6 to 1.0 V (26.6 kPa (199 mmHg, 7.85 in.Hg))

0.4 to 0.8 V (40 kPa (300 mmHg, 11.81 in.Hg))

1.2 to 1.5 V (19.6 kPa (0.20 kgf/cm2, 2.84 psi))

1.4 to 1.7 V (39.2 kPa (0.40 kgf/cm2, 5.69 psi))

1.6 to 1.9V (58.8 kPa (0.60 kgf/cm2, 8.53 psi))

1.8 to 2.1 V (78.5 kPa (0.80 kgf/cm2, 11.4 psi))

2.0 to 2.3 V (98.0 kPa (1.00 kgf/cm2, 14.2 psi))

No. 1 vacuum switching valve

1 - 2

1 - Body ground

2 - Body ground

Resistance:

33 to 39 Ω at 20°C (68°F)

10 kΩ or higher at always

10 kΩ or higher at always

No. 2 vacuum switching valve

1 - 2

1 - Body ground

2 - Body ground

Resistance:

33 to 39 Ω at 20°C (68°F)

10 kΩ or higher at always

10 kΩ or higher at always

Turbocharger

Axial play of turbine shaft

Radial play of turbine shaft

Maximum axial play:

0.11 mm (0.00433 in.)

Maximum radial play:

0.112 mm (0.00441 in.)