GLOW RELAY ON-VEHICLE INSPECTION


  1. INSPECT GLOW RELAY


    1. A01CHCWE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      Battery voltage (24 V) is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the glow relay.