STARTER RELAY INSTALLATION


  1. INSTALL STARTER RELAY ASSEMBLY


    1. Install the starter relay assembly with the 2 nuts.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    2. Connect the connector and attach the wire harness clamp.

    3. Connect the 2 lead wires to the starter relay assembly with the 2 nuts.

      Torque:
      4.7 N*m  { 48 kgf*cm, 42 in.*lbf }
    4. Install the terminal cap.

  2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.