COMMON RAIL INSPECTION


  1. INSPECT COMMON RAIL ASSEMBLY


    1. A01CHZ6

      Check the fuel pressure sensor.


      1. Using an ohmmeter, measure the resistance between the terminals.

        Standard resistance
        Terminal Condition Resistance
        1 (E2) - 2 (PR) 20°C (68°F) 16.4 kΩ or less
        2 (PR) - 3 (VC) 20°C (68°F) 3 kΩ or less