COMMON RAIL INSPECTION


  1. INSPECT COMMON RAIL ASSEMBLY


    1. A01CHQR

      Check the fuel pressure sensor.


      1. Using an ohmmeter, measure the resistance between the terminals.

        Standard resistance
        Tester Connection Specified Condition
        2 - 3 16.4 kΩ or less at 20°C (68°F)
        5 - 4 16.4 kΩ or less at 20°C (68°F)
        1 - 2 3 kΩ or less at 20°C (68°F)
        6 - 5 3 kΩ or less at 20°C (68°F)

        If the result is not as specified, replace the common rail assembly.