MANIFOLD ABSOLUTE PRESSURE SENSOR INSTALLATION


  1. INSTALL MANIFOLD ABSOLUTE PRESSURE SENSOR


    1. Install the manifold absolute pressure sensor with the 2 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    2. Install the No. 3 air hose, and slide the 2 hose clips to secure it.

    3. Connect the manifold absolute pressure sensor connector.