DESCRIPTION
The EGR system recirculates exhaust gases, in order to suit every driving condition. The recirculated gas mingles with the intake air, therefore the EGR system can slow combustion speed and keep the combustion temperature down. This helps reduce NOx emissions.
In order to increase EGR circulation efficiency, the ECM adjusts the lift amount of the EGR valve and intake shutter valve angle (throttle valve).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0400 | All of the following conditions are met (a) Battery voltage is 19.9 V or more (b) One of the following condition (1), (2) or (3) is met (1) Open or short in EGR valve circuit (2) Open or short in EGR vale position sensor circuit (3) EGR position are out of specified threshold and battery voltage 10 V or more |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
After replacing the ECM, the new ECM needs registration Click here and initialization Click here.
PROCEDURE
INSPECT EGR VALVE ASSEMBLY (RESISTANCE)
Disconnect the EGR valve connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the EGR valve connector.
| NG |
|
REPLACE EGR VALVE ASSEMBLY Click here |
| OK |
|
CHECK EGR VALVE ASSEMBLY (EGR VALVE POWER SOURCE)
Disconnect the EGR valve connector.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the EGR valve connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (EGR VALVE POSITION SENSOR - ENG-3 RELAY) |
| OK |
|
CHECK HARNESS AND CONNECTOR (EGR VALVE - ECM)
Disconnect the EGR valve connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
| Check for open | ||||||
|
||||||
| Check for short | ||||||
|
Reconnect the EGR valve connector.
Reconnect the ECM connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (EGR VALVE - ECM) |
| OK |
|
REPLACE ECM