N04C-TQ CHARGING SERVICE DATA

Battery Electrolyte volume 1.25 to 1.29 at 20°C (68°F)
Voltage 24.0 to 25.0 V at 20°C (68°F)
Charging circuit without load. Current 10 A or less
Voltage 25.0 to 26.0 V
Charging circuit with load. Current 30 A or more
Generator holder with rectifier Resistance Terminal B to Terminal P1, P2, P3, P4

Below 1 Ω (When the probes are connected one way)

10 kΩ or higher (When the probes are reversed)

Terminal E to Terminal P1, P2, P3, P4

Below 1 Ω (When the probes are connected one way)

10 kΩ or higher (When the probes are reversed)

Generator brush holder assembly Exposed brush length Standard 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum 1.5 mm (0.059 in.)
Generator rotor assembly Resistance Open circuit 10.6 to 11.4 Ω at 20°C (68°F)
Ground 10 MΩ or higher at 20°C (68°F)
Slip ring diameter Standard 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum 12.8 mm (0.504 in.)
Stator coil Resistance P1, P2, P4 and Drive end frame 10 kΩ or higher
P1, P2 and P3 1.5 Ω or lower