N04C-US COOLING SERVICE DATA

THERMOSTAT
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 mm (0.394 in.) or more at 95°C (203°F)
RADIATOR CAP SUB-ASSEMBLY
Condition Specified Condition
Standard value (for brand new cap)

93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)

Minimum standard value (for used cap)

78 kPa (0.8 kgf/cm2, 11.4 psi)