CAN COMMUNICATION SYSTEM Short to B+ in CAN Bus Line

DESCRIPTION

There may be a short circuit between the CAN bus lines and +B when the resistance between terminals 6 (CANH) and 16 (BAT) or terminals 14 (CANL) and 16 (BAT) of the DLC3 is below 6 kΩ.

Symptom Trouble Area
The resistance between terminals 6 (CANH) and 16 (BAT) or terminals 14 (CANL) and 16 (BAT) of the DLC3 is below 6 kΩ.
  • Short between CAN bus lines and +B

  • ECM

  • Electric vehicle control ECU assembly

  • Airbag ECU assembly

  • Brake actuator assembly (skid control ECU)

  • No. 1 junction connector

  • No. 2 junction connector

  • No. 3 junction connector

  • No. 4 junction connector

  • No. 5 junction connector

  • DLC3 CAN branch wire or connector

WIRING DIAGRAM

A01CIWYE02
A01CI8GE02

INSPECTION PROCEDURE

Note

The vehicle is equipped with an SRS (Supplemental Restraint System) which includes components such as airbags. Before servicing (including removal or installation of parts), be sure to read the Precaution in the SRS Click here.

Tech Tips

Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.


    NEXT
  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL


    1. Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the CAN main wire and the CAN branch wire.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the airbag system.

      Note

      When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.


    NEXT
  3. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (DLC3 CAN BRANCH WIRE)


    1. A01CH4ZE30
      Text in Illustration
      *a Front view of DLC3

      Disconnect the J72 No. 2 junction connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D34-6 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      D34-14 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  4. CONNECT CONNECTOR


    1. Reconnect the J72 No. 2 junction connector.


    NEXT
  5. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR SIDE)


    1. A01CH4ZE30
      Text in Illustration
      *a Front view of DLC3

      Disconnect the J76 No. 1 junction connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D34-6 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      D34-14 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  6. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - ELECTRIC VEHICLE CONTROL ECU ASSEMBLY)


    1. A01CGV9E57
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 1 Junction Connector)

      *b Front view of DLC3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J76-3 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J76-14 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J76-4 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J76-15 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  7. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - ECM)


    1. A01CGV9E58
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 1 Junction Connector)

      *b Front view of DLC3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J76-6 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J76-17 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  8. CONNECT CONNECTOR


    1. Reconnect the J76 No. 1 junction connector.


    NEXT
  9. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (ELECTRIC VEHICLE CONTROL ECU ASSEMBLY)


    1. A01CHISE05
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Electric Vehicle Control ECU Assembly)

      *b Front view of DLC3

      Disconnect the electric vehicle control ECU assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      E41-4 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      E41-5 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      E41-8 (CANP) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      E41-9 (CANN) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  10. CONNECT CONNECTOR


    1. Reconnect the J76 No. 1 junction connector.


    NEXT
  11. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (ECM)


    1. A01CHFCE07
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to ECM)

      *b Front view of DLC3

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      E40-7 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      E40-1 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  12. CONNECT CONNECTOR


    1. Reconnect the J76 No. 1 junction connector.


    NEXT
  13. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - NO. 1 JUNCTION CONNECTOR)


    1. A01CGV9E59
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 2 Junction Connector)

      *b Front view of DLC3

      Disconnect the No. 2 junction connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J72-6 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J72-17 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  14. CONNECT CONNECTOR


    1. Reconnect the J72 No. 2 junction connector.


    NEXT
  15. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR SIDE)


    1. A01CH4ZE30
      Text in Illustration
      *a Front view of DLC3

      Disconnect the J56 No. 4 junction connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D34-6 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      D34-14 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  16. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR - SKID CONTROL ECU)


    1. A01CHO7E39
      Text in Illustration
      *a

      Front view of wire harness connector

      (to No. 4 Junction Connector)

      *b Front view of DLC3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J56-4 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J56-9 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  17. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR - NO. 5 JUNCTION CONNECTOR)


    1. A01CHO7E40
      Text in Illustration
      *a

      Front view of wire harness connector

      (to No. 4 Junction Connector)

      *b Front view of DLC3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J56-5 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J56-10 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  18. CONNECT CONNECTOR


    1. Reconnect the J56 No. 4 junction connector.


    NEXT
  19. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (SKID CONTROL ECU)


    1. A01CHMJE07
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Brake Actuator Assembly [Skid Control ECU])

      *b Front view of DLC3

      Disconnect the brake actuator assembly (skid control ECU) connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      B9-15 (CH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      B9-26 (CL-) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  20. CONNECT CONNECTOR


    1. Reconnect the J56 No. 4 junction connector.


    NEXT
  21. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 5 JUNCTION CONNECTOR)


    1. A01CHRPE03
      Text in Illustration
      *a

      Front view of wire harness connector

      (to No. 5 Junction Connector)

      *b Front view of DLC3

      Disconnect the No. 5 junction connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J84-1 (CA1H) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J84-2 (CA1L) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  22. CONNECT CONNECTOR


    1. Reconnect the J56 No. 4 junction connector.


    NEXT
  23. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 3 JUNCTION CONNECTOR - NO. 4 JUNCTION CONNECTOR)


    1. A01CGV9E71
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 3 Junction Connector)

      *b Front view of DLC3

      Disconnect the No. 3 junction connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J82-9 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J82-20 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  24. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 3 JUNCTION CONNECTOR SIDE)


    1. A01CH4ZE30
      Text in Illustration
      *a Front view of DLC3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D34-6 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      D34-14 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  25. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 3 JUNCTION CONNECTOR - TACHOGRAPH ASSEMBLY)


    1. A01CGV9E72
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 3 Junction Connector)

      *b Front view of DLC3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J82-7 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J82-18 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  26. CONNECT CONNECTOR


    1. Reconnect the J82 No. 3 junction connector.


    NEXT
  27. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - AIRBAG ECU ASSEMBLY)


    1. A01CGV9E62
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 2 Junction Connector)

      *b Front view of DLC3

      Disconnect the No. 2 junction connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J72-3 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J72-14 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  28. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - NO. 3 JUNCTION CONNECTOR)


    1. A01CGV9E63
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 2 Junction Connector)

      *b Front view of DLC3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      J72-5 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      J72-16 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  29. CONNECT CONNECTOR


    1. Reconnect the J72 No. 2 junction connector.


    NEXT
  30. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (AIRBAG ECU ASSEMBLY)


    1. A01CHRJE03
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Airbag ECU Assembly)

      *b Front view of DLC3

      Disconnect the airbag ECU assembly connector Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A30-18 (CANH) - D34-16 (BAT) Ignition switch off 6 kΩ or higher
      A30-10 (CANL) - D34-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK