| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| EEPROM cannot determine constant value due to EEPROM reading malfunction or other malfunction | Default control | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Engine revolution signal is interrupted for 0.12 seconds | Controls input signals as 0 rpm | Normal data is received |
| EEPROM cannot determine constant value due to EEPROM reading malfunction or other malfunction | Default control | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| EEPROM cannot determine constant value due to EEPROM reading malfunction or other malfunction | Default control | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While ignition switch is ON, engine coolant temperature data is interrupted for 3.1 seconds | The segment is assumed turning off | Normal data is received |
| EEPROM cannot determine constant value due to EEPROM reading malfunction or other malfunction | Default control | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| EEPROM (ODO data) is abnormal | The display becomes blank | Normal data is received |
| EEPROM cannot determine constant value due to EEPROM reading malfunction or other malfunction | Default control | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| EEPROM cannot determine constant value due to EEPROM reading malfunction or other malfunction | Default control | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While ignition switch is ON, exhaust brake warning light signal is interrupted for 3.1 seconds | Exhaust brake warning light condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While ignition switch is ON, oil pressure warning light signal is interrupted for 3.1 seconds | Oil pressure warning light condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While ignition switch is ON, brake warning light signal is interrupted for 3.1 seconds | Brake warning light condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While ignition switch is ON, ABS warning light signal is interrupted for 3.1 seconds | ABS warning light remains on until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While ignition switch is ON, sedimenter warning light signal is interrupted for 3.1 seconds | Sedimenter warning light remains on until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While ignition switch is ON, charge warning light signal is interrupted for 3.1 seconds | Charge warning light remains on until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While ignition switch is ON, ECO indicator light signal is interrupted for 3.1 seconds | ECO indicator light remains on until ignition switch off | Normal data is received |
| EEPROM cannot determine constant value due to EEPROM reading malfunction or other malfunction | Default control | Normal data is received |