STOP LIGHT SWITCH INSPECTION

PROCEDURE


  1. INSPECT STOP LAMP SWITCH ASSEMBLY (for Bulb Type Stop Light)


    1. Check the resistance.


      1. A01VIV0E02
        Text in Illustration
        *a

        Component without harness connected

        (Stop Light Switch Assembly)

        *b Not Pushed
        *c Pushed
        *d Switch Pin

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        1 - 2 Not pushed Below 1 Ω
        Pushed 10 kΩ or higher
        3 - 4 Not pushed 10 kΩ or higher
        Pushed Below 1 Ω

        If the result is not as specified, replace the stop light switch assembly.