HAZARD WARNING SWITCH INSPECTION

PROCEDURE


  1. INSPECT TELLTALE LIGHT ASSEMBLY (for TMMF Made)


    1. A01VE7PE04
      Text in Illustration
      *a

      Component without harness connected

      (Telltale Light Assembly)

      Check the hazard warning signal light switch function.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance:
        Tester Connection Switch Condition Specified Condition
        4(TB) - 5(E) Pushed Below 1 Ω
        Not pushed 10 kΩ or higher

        If the result is not as specified, replace the telltale light assembly.

    2. A01VE7PE04
      Text in Illustration
      *a

      Component without harness connected

      (Telltale Light Assembly)

      Check the illumination operation.


      1. Apply battery voltage to the telltale light assembly connector.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 6(DIM)

        Battery positive (-) → 5(E)

        The illumination comes on

        If the result is not as specified, replace the telltale light assembly.