LIGHTING SYSTEM Hazard Warning Switch Circuit

DESCRIPTION

The combination meter assembly receives information signals from the telltale light assembly (hazard warning signal switch).

WIRING DIAGRAM

A01VLKDE01

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Combination Meter / Data List.

    5. According to the display on the intelligent tester, read the Data List.

      Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Hazard Flasher Switch

      Hazard warning signal switch /

      OFF or ON

      OFF: Hazard warning signal switch off

      ON: Hazard warning signal switch on

      -
      OK
      Normal conditions listed above are displayed.

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY)

    A01VHL4E01
    Text in Illustration
    *a

    Front view of wire harness connector

    (to Combination Meter Assembly)


    1. Disconnect the F3 combination meter assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      F3-1 (B) - Body Ground Always 11 to 14 V

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (TELLTALE LIGHT ASSEMBLY (HAZARD WARNING SIGNAL SWITCH) - COMBINATION METER ASSEMBLY)


    1. Disconnect the F93 telltale light assembly (hazard warning signal switch) connector.

    2. Disconnect the F3 combination meter assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F93-4 (TB) - F3-3 (HAZ) Always Below 1 Ω
      F93-5 (E) - Body Ground Always Below 1 Ω
      F93-4 (TB) - Body ground Always 10 kΩ or higher

    NG
    OK
  4. REPLACE TELLTALE LIGHT ASSEMBLY (HAZARD WARNING SIGNAL SWITCH)


    1. Temporarily replace the telltale light assembly (hazard warning signal switch) with a new functioning one Click here.


    NEXT
  5. READ VALUE USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Combination Meter / Data List.

    5. According to the display on the intelligent tester, read the Data List.

      Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Hazard Flasher Switch

      Hazard warning signal switch /

      OFF or ON

      OFF: Hazard warning signal switch off

      ON: Hazard warning signal switch on

      -
      OK
      Normal conditions listed above are displayed.

    OK
    NG