DESCRIPTION
The jam protection function operates within a specified range during the manual up or auto up operation.
Tech Tips
This symptom may occur only in the driver side window.
CAUTION / NOTICE / HINT
Note
The power window control system uses a LIN communication system. Inspect the communication function by following How to Proceed with Troubleshooting Click here. Troubleshoot the power window control system after confirming that the communication system is functioning properly.
When the power window regulator motor assembly LH or RH (driver side) is reinstalled or replaced, the power window control system must be initialized.
After a door glass or a door glass run has been replaced, the jam protection function may operate unexpectedly when the auto up function is used. In such cases, the auto up function can be resumed by repeating the following operations at least 5 times:
Close the power window by fully pulling up the power window regulator master switch assembly and holding it in the auto up position.
Open the power window by fully pushing down the power window regulator master switch assembly.
PROCEDURE
PERFORM INITIALIZATION (DRIVER SIDE)
Initialize the power window regulator motor assembly LH or RH (driver side) Click here.
| NEXT |
|
CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)
Check if the driver side power window auto up and down function operates normally Click here.
| OK |
|---|
| Auto up and down function is normal. |
| NG |
|
GO TO OTHER PROBLEM (Proceed to Problem Symptoms Table) Click here |
| OK |
|
CHECK JAM PROTECTION FUNCTION OPERATING RANGE
Check if the jam protection function operates normally for the driver side power window.
Tech Tips
The jam protection function will not operate within 4 mm (0.157 in.) of the fully closed position.
| OK |
|---|
| Jam protection function operates normally. |
| OK |
|
END (PROBLEM DUE TO INITIALIZATION FAILURE) |
| NG |
|
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY LH OR RH (DRIVER SIDE) Click here |