PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE FAN AND GENERATOR V BELT
REMOVE ENGINE UNDER COVER RH
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the suction hose from the compressor.
Remove the O-ring from the suction hose.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE
Remove the bolt and disconnect the discharge hose from the compressor.
Remove the O-ring from the discharge hose.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
REMOVE COMPRESSOR WITH PULLEY ASSEMBLY
Disconnect the connector.
Remove the 4 bolts and the compressor.