PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
REMOVE FAN AND GENERATOR V BELT
REMOVE ENGINE UNDER COVER RH
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Disconnect the connector.
Remove the bolt and disconnect the suction hose sub-assembly from the compressor with pulley assembly.
Remove the O-ring from the suction hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE
Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose from the compressor with pulley assembly.
Remove the O-ring from the No. 1 cooler refrigerant discharge hose.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
REMOVE COMPRESSOR WITH PULLEY ASSEMBLY
Remove the 3 bolts and nut.
Using a "TORX" socket wrench (E8), remove the stud bolt and the compressor with pulley assembly.