FRONT BLOWER MOTOR REMOVAL

PROCEDURE


  1. REMOVE NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY

    Click here

  2. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY (for Automatic Air Conditioning System)


    1. A01VIR5

      Disconnect the connector.

    2. Remove the 3 screws and the blower motor.

  3. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY (for Manual Air Conditioning System)


    1. A01VKFL

      Disengage the clamp.

    2. Disconnect the connector.

    3. Remove the 3 screws and the blower motor.