COMPRESSOR(for 1ND-TV) INSPECTION

PROCEDURE


  1. INSPECT COMPRESSOR WITH PULLEY ASSEMBLY


    1. A01VEH8E04
      Text in Illustration
      *a

      Component without harness connected

      (Compressor With Pulley Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (SOL+) - 1 (SOL-) 20°C (68°F) 10 to 11 Ω

      • If the result is not as specified, replace the compressor with pulley assembly.