| DTC Code | DTC Name |
|---|---|
| B1413 | Evaporator Temperature Sensor Circuit |
DESCRIPTION
The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as the resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes. This sensor is used for frost prevention.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1413 | An open or short in the No. 1 cooler thermistor (evaporator temperature sensor) circuit. |
|
WIRING DIAGRAM
| *a | No. 1 Cooler Thermistor (Evaporator Temperature Sensor) |
| *b | Air Conditioning Amplifier Assembly |
PROCEDURE
READ VALUE USING INTELLIGENT TESTER
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Evaporator Fin Thermistor | Evaporator temperature sensor/ Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F). Short in the circuit: 59.55°C (139.19°F). |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) Click here |
| A |
|
CHECK FOR DTC
Clear the DTCs Click here.
Check for DTCs Click here.
| OK |
|---|
| DTC B1413 is not output |
| OK |
|
USE SIMULATION METHOD TO CHECK Click here |
| NG |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR)
Inspect the No. 1 cooler thermistor (evaporator temperature sensor) Click here.
| NG |
|
REPLACE NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the F32 No. 1 cooler thermistor (evaporator temperature sensor) connector.
Disconnect the F41 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|