AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System), Diagnostic DTC:B1413/13

DTC Code DTC Name
B1413/13 Evaporator Temperature Sensor Circuit

DESCRIPTION

The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as the resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes. This sensor is used for frost prevention.

DTC No. DTC Detection Condition Trouble Area
B1413/13 An open or short in the No. 1 cooler thermistor (evaporator temperature sensor) circuit.
  • No. 1 cooler thermistor (evaporator temperature sensor)

  • Air conditioning harness assembly

  • Air conditioning amplifier assembly

WIRING DIAGRAM

B0046TNE03

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Data List.

    5. According to the display on the intelligent tester, read the Data List.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Evaporator Fin Thermistor

      Evaporator temperature sensor /

      Min.: -29.7°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed

      Open in the circuit: -29.7°C (-21.46°F).

      Short in the circuit: 59.55°C (139.19°F).

      OK
      The display is as specified in the normal condition column.
      Result
      Result Proceed to
      OK (When troubleshooting according to the DTC) A
      OK (When troubleshooting according to Problem Symptoms Table) B
      NG C

    B
    C
    A
  2. CHECK FOR DTC


    1. Clear the DTCs Click here.

    2. Check for DTCs Click here.

      OK
      DTC B1413/13 is not output

    OK
    NG
  3. INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR)


    1. Inspect the No. 1 cooler thermistor (evaporator temperature sensor) Click here.


    NG
    OK
  4. INSPECT AIR CONDITIONING HARNESS ASSEMBLY (NO. 1 COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)


    1. Remove the air conditioning harness assembly.

    2. B0046EBE02
      Text in Illustration
      *1 Air Conditioning Harness Assembly

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-2 - z4-6 (TEA) Always Below 1 Ω
      A-1 - z4-5 (SGA) Always Below 1 Ω
      A-2 - Body ground Always 10 kΩ or higher
      A-1 - Body ground Always 10 kΩ or higher

    OK
    NG