DATA LIST
Tech Tips
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus:
for Air conditioning Amplifier:
Body / Air Conditioner / Data List
for Combination Meter:
Body / Combination Meter / Data List
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.1°F) |
Actual room temperature is displayed | - |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature is displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F). Short in the circuit: 59.55°C (139.19°F). |
| Evaporator Target Temp | Target evaporator temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Target evaporator temperature displayed | - |
| Solar Sensor (D side) | Driver side solar sensor / Min.: 0 Max.: 255 |
Driver side solar sensor value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature is displayed after engine warmed up | - |
| Set Temperature (D side) | Driver side set temperature / Min.: MAX COLD Max.: MAX HOT |
Driver side actual set temperature is displayed | - |
| Set Temperature (P side) | Front passenger side set temperature / Min.: MAX COLD Max.: MAX HOT |
Front passenger side actual set temperature is displayed | - |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0 Max.: 31 |
Increases from 0 to 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Regulator pressure sensor / Min.: -0.4566 MPaG Max.: 3.2943 MPaG |
Actual regulator pressure is displayed | - |
| Regulator Control Current | Regulator control current / Min.: 0 A Max.: 0.997 A |
Value changes between 0.12 A and 0.997 A in accordance with compressor and magnetic clutch operation | - |
| Air Mix Servo Targ Pulse (D) | Air mix servo motor target pulse (driver side) / Min.: 0 Max.: 255 |
|
- |
| Air Mix Servo Actual Pulse (D) | Air mix servo motor actual pulse (driver side) / Min.: 0 Max.: 255 |
Follows the target pulse | - |
| Air Mix Servo Targ Pulse (P) | Air mix servo motor target pulse (front passenger side) / Min.: 0 Max.: 255 |
|
- |
| Air Mix Servo Actual Pulse (P) | Air mix servo motor actual pulse (front passenger side) / Min.: 0 Max.: 255 |
Follows the target pulse | - |
| Air Outlet Servo Pulse (D) | Air outlet servo motor target pulse / Min.: 0 Max.: 255 |
|
- |
| Air Outlet Servo Actu Pulse (D) | Air outlet servo motor actual pulse / Min.: 0 Max.: 255 |
Follows the target pulse | - |
| Air Inlet Damper Targ Pulse | Air inlet servo motor target pulse / Min.: 0 Max.: 255 |
|
- |
| Air Inlet Damper Actual Pulse | Air inlet servo motor actual pulse / Min.: 0 Max.: 255 |
Follows the target pulse | - |
| Electric Heater Count*1 | Target number of electric heaters operating / Min.: 0 Max.: 3 |
- | - |
| Electric Heater Active Level*1 | Number of electric heaters operating / Min.: 0 Max.: 3 |
Follows the target number | - |
| Shift Set Temperature | Set temperature shift / 2C decr, 1C decr, Normal, 1C incr or 2C incr |
Customized value displayed | - |
| Air Inlet Mode | Air inlet mode / Auto or Manual |
Customized value displayed | - |
| Evaporator Control | Evaporator Control / Auto or Manual |
Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant shortage check function / ON or OFF |
Customized value displayed | - |
| Fan Speed Increment Control | Blower motor speed increment level to target speed / Fast, Normal or Slow |
Customized value displayed | - |
| Foot/DEF Auto Mode | Foot / DEF auto mode / ON or OFF |
Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot / DEF automatic blow up function / ON or OFF |
Customized value displayed | - |
| Pls Servo Test Sts | Pulse servo motor test status / Wait, Move, Comp, Error or Stop | Pulse servo motor test status | - |
| A/C Cutoff Signal | A/C control cutoff signal / ON or OFF |
- | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
*1: w/ PTC Heater
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Ambient Temperature | Ambient temperature sensor / Min.: -40°C (-40°F) Max.: 87.5°C (189.5°F) |
Actual ambient temperature is displayed | - |
ACTIVE TEST
Tech Tips
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Air Conditioner: Body / Air Conditioner / Active Test.
According to the display on the intelligent tester, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Magnetic Clutch Relay | A/C Compressor | OFF or ON | - |
| Defogger Relay (Rear) | Defogger relay (Rear) | OFF or ON | - |
| Heater Active Level*1 | Heater level | Min.: 0, Max.: 3 | - |
| Air Mix Servo Targ Pulse (D) | Air mix servo motor pulse (driver side) | Min.: 0, Max.: 255 | Perform Active Test when value between 4 and 93 displayed |
| Air Mix Servo Targ Pulse (P) | Air mix servo motor pulse (front passenger side) | Min.: 0, Max.: 255 | Perform Active Test when value between 4 and 93 displayed |
| Air Outlet Servo Pulse (D) | Air outlet servo motor pulse | Min.: 0, Max.: 255 | Perform Active Test when value between 9 and 101 displayed |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse | Min.: 0, Max.: 255 | Perform Active Test when value between 6 and 22 displayed |
*1: w/ PTC Heater