CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (w/ Cooler)
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| F41-1 (IG+) - F41-23 (GND) | V - W-B | Ignition power supply | Ignition switch: ON | 11 to 14 V |
| F41-2 (A/C) - F41-23 (GND) | G - W-B | A/C switch signal | Ignition switch: ON | Below 1 V → 11 to 14 V |
| Defroster: OFF | ||||
| A/C switch: OFF → ON | ||||
| F41-3 (HEAT) - Body ground*1 | LG - Body ground | MAX HOT switch detection signal | Ignition switch: ON | 11 to 14 V |
| No. 3 heater control knob: MAX HOT | ||||
| F41-4 (TE) - F41-15 (SG- 1) | GR - B | Evaporator temperature sensor signal | Ignition switch: ON | 1.0 to 1.3 V |
| Temperature near evaporator: 15°C (59°F) | ||||
| F41-5 (SG-2) - Body ground | L - Body ground | Ground for A/ C pressure sensor | Always | Below 1 Ω |
| F41-7 (PRE) - F41-23 (GND) | GR - W-B | A/C pressure sensor signal | Refrigerant pressure: Normal | 0.74 to 4.62 V |
| Refrigerant pressure: Abnormal (less than 0.176 MPaG [1.8 kgf/cm2] or more than 3.03 MPaG [31 kgf/cm2]) |
Below 0.74 V or 4.62 V or more | |||
| F41-8 (TX+) - F41-23 (GND) | V - W-B | CAN communication signal | Ignition switch: ON | Pulse generation (See waveform 1) |
| F41-9 (TX-) - F41-23 (GND) | W - W-B | CAN communication signal | Ignition switch: ON | Pulse generation (See waveform 2) |
| F41-11 (SOL+) - F41-23 (GND) | P - W-B | A/C compressor operation signal | Engine idling | Pulse generation (See waveform 3) |
| Blower switch: 1 | ||||
| A/C switch: ON | ||||
| F41-13 (PTC1) - Body ground*1 | SB - Body ground | Quick heater assembly relay operation signal | Engine idling | 11 to 14 V → Below 1 V |
| No. 3 heater control knob: MAX HOT | ||||
| Engine coolant temperature: Below 75°C (167°F) | ||||
| Ambient temperature: Below 10°C (50°F) | ||||
| Blower switch: 0 → 1 | ||||
| Waiting time: 10 seconds | ||||
| F41-14 (HR) - Body ground | R - Body ground | Heater blower motor relay operation signal | Ignition switch: ON | 11 to 14 V → Below 1 V |
| Blower switch: 0 → 1 | ||||
| F41-15 (SG-1) - Body ground | B - Body ground | Ground for evaporator temperature sensor | Always | Below 1 Ω |
| F41-16 (LED) - Body ground | BE - Body ground | A/C switch indicator signal | Engine idling | 11 to 14 V → Below 4 V |
| A/C switch: ON | ||||
| Blower switch: 0 → 1 | ||||
| F41-17 (SBLW) - Body ground | GR - Body ground | Blower motor ON signal | Ignition switch: ON | 11 to 14 V → Below 1 V |
| Blower switch: 0 → 1 | ||||
| F41-19 (PTC2) - Body ground*1 | P - Body ground | Quick heater assembly relay operation signal | Engine idling | 11 to 14 V → Below 1 V |
| No. 3 heater control knob: MAX HOT | ||||
| Engine coolant temperature: Below 70°C (158°F) | ||||
| Ambient temperature: Below 10°C (50°F) | ||||
| Blower switch: 0 → 1 | ||||
| Waiting time: 20 seconds | ||||
| F41-20 (PTC3) - Body ground*1 | V - Body ground | Quick heater assembly relay operation signal | Engine idling | 11 to 14 V → Below 1 V |
| No. 3 heater control knob: MAX HOT | ||||
| Engine coolant temperature: Below 65°C (149°F) | ||||
| Ambient temperature: Below 10°C (50°F) | ||||
| Blower switch: 0 → 1 | ||||
| Waiting time: 30 seconds | ||||
| F41-21 (HLS) - Body ground*1 | R - Body ground | Headlight signal | Engine idling Head light switch: OFF → ON |
11 to 14 V → Below 1 V |
| F41-23 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 Ω |
| F41-24 (S5-3) - F41-23 (GND) | Y - W-B | Power supply for pressure sensor | Ignition switch: ON | 4.75 to 5.25 V |
*1: w/ PTC Heater
If the result is not as specified, there may be a malfunction in the wire harness.
| *a | 1 V/DIV. |
| *b | 10 μsec./DIV. |
Waveform 1 (Reference) : Using an oscilloscope
| Terminal Name | F41-8 (TX+) - F41-23 (GND) |
| Tester Range | 1 V / DIV., 10 μsec. / DIV. |
| Condition | Ignition switch ON |
Tech Tips
The waveform varies depending on the CAN communication signal.
| *a | 1 V/DIV. |
| *b | 10 μsec./DIV. |
Waveform 2 (Reference) : Using an oscilloscope
| Terminal Name | F41-9 (TX-) - F41-23 (GND) |
| Tester Range | 1 V / DIV., 10 μsec. / DIV. |
| Condition | Ignition switch ON |
Tech Tips
The waveform varies depending on the CAN communication signal.
| *a | 5 V/DIV. |
| *b | 500 μsec/DIV. |
Waveform 3: Using an oscilloscope
| Terminal Name | F41-11 (SOL+) - F41-23 (GND) |
| Tester Range | 5 V / DIV., 500 μsec. / DIV. |
| Condition | Engine idling Blower switch 1 A/C switch ON |
CHECK COMBINATION METER ASSEMBLY (w/ Cooler)
Tech Tips
Check from the rear of the connector while it is connected to the combination meter assembly.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| F1-34 (TX1-) - Body ground | B - Body ground | Ground for ambient temperature sensor | Always | Below 1 Ω |
| F1-35 (TX1+) - F1-34 (TX1-) | W - B | Ambient temperature sensor signal | Ignition switch ON at 25°C (77°F) | 1.35 to 1.75 V |
| F1-39 (IG+) - Body ground | P - Body ground | Ignition power supply | Ignition switch ON | 11 to 14 V |
| F1-40 (B) - Body ground | L - Body ground | Battery power supply | Always | 11 to 14 V |
If the result is not as specified, there may be a malfunction in the wire harness.
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (w/o Cooler)
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| F41-1 (IG+) - F41-23 (GND)*1 | V - W-B | Ignition power supply | Ignition switch: ON | 11 to 14 V |
| F41-3 (HEAT) - Body ground*1 | LG - Body ground | MAX HOT switch detection signal | Ignition switch: ON | 11 to 14 V |
| No. 3 heater control knob: MAX HOT | ||||
| F41-8 (TX+) - F41-23 (GND)*1 | V - W-B | CAN communication signal | Ignition switch: ON | Pulse generation (See waveform 1) |
| F41-9 (TX-) - F41-23 (GND)*1 | W - W-B | CAN communication signal | Ignition switch: ON | Pulse generation (See waveform 2) |
| F41-13 (PTC1) - Body ground*1 | SB - Body ground | Quick heater assembly relay operation signal | Engine idling | 11 to 14 V → Below 1 V |
| No. 3 heater control knob: MAX HOT | ||||
| Engine coolant temperature: Below 75°C (167°F) | ||||
| Ambient temperature: Below 10°C (50°F) | ||||
| Blower switch: 0 → 1 | ||||
| Waiting time: 10 seconds | ||||
| F41-14 (HR) - Body ground | R - Body ground | Heater blower motor relay operation signal | Ignition switch: ON | 11 to 14 V → Below 1 V |
| Blower switch: 0 → 1 | ||||
| F41-17 (SBLW) - Body ground | GR - Body ground | Blower motor ON signal | Ignition switch: ON | 11 to 14 V → Below 1 V |
| Blower switch: 0 → 1 | ||||
| F41-19 (PTC2) - Body ground*1 | P - Body ground | Quick heater assembly relay operation signal | Engine idling | 11 to 14 V → Below 1 V |
| No. 3 heater control knob: MAX HOT | ||||
| Engine coolant temperature: Below 70°C (158°F) | ||||
| Ambient temperature: Below 10°C (50°F) | ||||
| Blower switch: 0 → 1 | ||||
| Waiting time: 20 seconds | ||||
| F41-20 (PTC3) - Body ground*1 | V - Body ground | Quick heater assembly relay operation signal | Engine idling | 11 to 14 V → Below 1 V |
| No. 3 heater control knob: MAX HOT | ||||
| Engine coolant temperature: Below 65°C (149°F) | ||||
| Ambient temperature: Below 10°C (50°F) | ||||
| Blower switch: 0 → 1 | ||||
| Waiting time: 30 seconds | ||||
| F41-21 (HLS) - Body ground*1 | R - Body ground | Headlight signal | Engine idling Head light switch: OFF → ON |
11 to 14 V → Below 1 V |
| F41-23 (GND) - Body ground*1 | W-B - Body ground | Ground for main power supply | Always | Below 1 Ω |
*1: w/ PTC Heater
If the result is not as specified, there may be a malfunction in the wire harness.
| *a | 1 V/DIV. |
| *b | 10 μsec./DIV. |
Waveform 1 (Reference) : Using an oscilloscope
| Terminal Name | F41-8 (TX+) - F41-23 (GND) |
| Tester Range | 1 V / DIV., 10 μsec. / DIV. |
| Condition | Ignition switch ON |
Tech Tips
The waveform varies depending on the CAN communication signal.
| *a | 1 V/DIV. |
| *b | 10 μsec./DIV. |
Waveform 2 (Reference) : Using an oscilloscope
| Terminal Name | F41-9 (TX-) - F41-23 (GND) |
| Tester Range | 1 V / DIV., 10 μsec. / DIV. |
| Condition | Ignition switch ON |
Tech Tips
The waveform varies depending on the CAN communication signal.
CHECK COMBINATION METER ASSEMBLY (w/o Cooler)
Tech Tips
Check from the rear of the connector while it is connected to the combination meter assembly.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| F1-34 (TX1-) - Body ground*1 | B - Body ground | Ground for ambient temperature sensor | Always | Below 1 Ω |
| F1-35 (TX1+) - F1-34 (TX1-)*1 | W - B | Ambient temperature sensor signal | Ignition switch ON at 25°C (77°F) | 1.35 to 1.75 V |
| F1-39 (IG+) - Body ground | P - Body ground | Ignition power supply | Ignition switch ON | 11 to 14 V |
| F1-40 (B) - Body ground | L - Body ground | Battery power supply | Always | 11 to 14 V |
*1: w/ PTC Heater
If the result is not as specified, there may be a malfunction in the wire harness.