DOOR CONTROL SWITCH INSPECTION

PROCEDURE


  1. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (w/o Rear Power Window)


    1. A01VIXOE01
      Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Master Switch Assembly)

      *b LOCK
      *c UNLOCK

      for LHD:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        3 (L) - 7 (GND) LOCK Below 1 Ω
        OFF 10 kΩ or higher
        9 (UL) - 7 (GND) UNLOCK Below 1 Ω
        OFF 10 kΩ or higher

        If the result is not as specified, replace the power window regulator master switch.

    2. A01VGMVE04
      Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Master Switch Assembly)

      *b LOCK
      *c UNLOCK

      for RHD:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (L) - 7 (GND) LOCK Below 1 Ω
        OFF 10 kΩ or higher
        3 (UL) - 7 (GND) UNLOCK Below 1 Ω
        OFF 10 kΩ or higher

        If the result is not as specified, replace the power window regulator master switch.

  2. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (w/ Rear Power Window)


    1. A01VGNYE05
      Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Master Switch Assembly)

      *b LOCK
      *c UNLOCK

      for LHD:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        2 (L) - 1 (GND) LOCK Below 1 Ω
        OFF 10 kΩ or higher
        9 (UL) - 1 (GND) UNLOCK Below 1 Ω
        OFF 10 kΩ or higher

        If the result is not as specified, replace the power window regulator master switch.

    2. A01VHHFE05
      Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Master Switch Assembly)

      *b LOCK
      *c UNLOCK

      for RHD:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        2 (L) - 9 (GND) LOCK Below 1 Ω
        OFF 10 kΩ or higher
        8 (UL) - 9 (GND) UNLOCK Below 1 Ω
        OFF 10 kΩ or higher

        If the result is not as specified, replace the power window regulator master switch.

  3. INSPECT DOOR CONTROL SWITCH ASSEMBLY (w/o Power Window)


    1. A01VEVDE03
      Text in Illustration
      *a

      Component without harness connected

      (Door Control Switch Assembly)

      *b LOCK
      *c UNLOCK

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (L) - 3 (E) LOCK Below 1 Ω
      OFF 10 kΩ or higher
      2 (UL) - 3 (E) UNLOCK Below 1 Ω
      OFF 10 kΩ or higher

      If the result is not as specified, replace the door control switch.